OWI™ - Optical Weather Identifier (OWI-120): Affordable Present Weather

wpe11.gif (10862 bytes)

Advantages

+Easy to Install/Maintain
+Measures Liquid & Frozen Precipitation Rate
+Optically Detects Precipitation Type
+Wide Dynamic Range (measures from .25 to 3000 mm/hr)
+Operates unattended 24 hours a day, 7 days a week
+Not Effected by Fog, Debris, Dust
+Links directly to PC; Simple ASCII Data Format

Description

OWI™ offers the user a present weather sensor with performance that rivals the LEDWI® but at a lower cost. Based on the design concepts of the field proven LEDWI® and WIVIS®, it has excellent performance but with slightly reduced EMI and operating temperature specifications, and without hood heaters.

Like its counterpart, the WIVIS®, the OWI™ is an excellent road weather instrument. The only differences are: 1) the WIVIS® comes with visibility sensing while the OWI™ does not and 2) the OWI™ is lower in cost than the WIVIS®.

Many of the OWI™ features make the instrument excellent for efficient, real-time, remote weather sensing. The OWI™ provides present weather information such as precipitation rate and type in a digital RS-232 output format. You can link the sensor directly to your PC. The output comes in both NWS and WMO code formats. The OWI's small weight and size make it easy to handle. While the OWI's U-bolts configuration gives the user an easy and flexible method of installation.

Ordering Information
Specify OWI-120-xR where "x"=
»A for 110 VAC  
»B for 220 VAC
»C for 100 VAC
»D for 12 VDC

»E for 230 VAC

Options
-QCS-120 QwikCollect Software for OWI
-TST-120 Field Test Kit for OWI
-HIP-100 Hail & Ice Pellet Sensor for OWI

Contact factory for special options such as relay outputs, limited distance modems, etc.

Specifications

Performance Specifications

Rain Dynamic Range 0.1 to 3000 mm/hr
Snow Dynamic Range 0.05 to 1000 mm/hr (water equivalent)
Present Weather Codes More than 50 NWS and WMO codes

Electrical Specifications

Power Requirements Factory selectable, 100/115/220/230 VAC, 50/60 Hz @ 80 VA - 12 VDC optional, 20 VA nominal
Signal Output RS-232 ASCII

Environmental Specifications

Temperature Range -40 to 50 C
Humidity Range 0-100%
Precipitation/Dust NEMA-4 type protection

Physical Specifications

Head Size 737 x 102 x 254 mm (29 x 4 x 10 in.)
Enclosure Size 457 x 305 x 230 mm (18 x 12 x 9 in.)
Head Weight 4.5 kg (10 lbs.)
Enclosure Size 11 kg (24.2 lbs.)
Head & Enclosure Cable Length 5 m (16.4 ft.)
Present Weather Codes More than 50 NWS and WMO codes